On Mon, Oct 02, 2000 at 03:46:03PM -0500, Dave Plonka wrote:
> Anyone out there have experience (good or bad) with the PA-A3 OC12 card
> in a 7500 series router? My coworkers have scheduled an "emergency"
> upgrade for tomorrow AM to put this thing into a production router
> without my having a chance to test it with v5 export beforehand.
Just answering my own question here, for the benefit of anyone else who
does this in the future:
NetFlow v5 flow export did continue to work find on one of our 7500
series router after replacing an OC3 with the PA-A3 OC12 and upgrading
from RSP4 to RSP8.
Now, how to get the CISCO-CAR-MIB to work on the 75xx?
I am not able to select the CISC-CAR-MIB objects from our 75xx router
running 12.0(13)S, but I am able to select it from a GSR running
12.0(11)S3:
$ snmpwalk <router> <community> .1.3.6.1.4.1.9.9.113 # ciscoCarMIB
While it doesn't seem cflowd related, what I want to do is to collect
the CAR stats and correlate them with the flow stats in near
real-time.
Please email if you think it's off topic, but have some insight.
Thanks,
Dave
-- plonka@doit.wisc.edu http://net.doit.wisc.edu/~plonka ARS:N9HZF Madison, WI -- cflowd mailing list cflowd@caida.org
This archive was generated by hypermail 2b29 : Wed Oct 04 2000 - 22:55:30 PDT