Hello Benoit, Jesper,
no not really. I changed it to v5. The IOS is Version 12.0(10r)S1.
Never had a problem with that before. With an earlier version
i had problems getting the dot1q encapsulation on the gigabit
interface working. I have some subinterface with dot1q
encapsulation configured on the exporting interface. Could that
be a problem?
Best regards,
Christian Braun.
On Wed, Jun 06, 2001 at 04:33:42PM +0200, Benoit Claise wrote:
> Hi Hielke,
>
> Before starting troubleshooting, is there a reason why you use netflow
> version 6?
> Version 6 has been developped for one customer only.
> You should go to version 5.
>
> Regards, Benoit
>
> Hielke Christian Braun wrote:
>
> > Hello,
> >
> > i got the problem that in all exported flows the source as is
> > set to 0. When i disable distributed cef everthing is working fine.
> > Naturally this is not an option.
> > Is anybody using cflow with a cisco 7500 and distributed cef? Is
> > there some magic configuration options for the cisco?
> >
> > Here is mine:
> >
> > ip cef distributed
> > !
> > interface GigabitEthernet1/0/0
> > ip address 10.2.1.1 255.255.255.0
> > no ip directed-broadcast
> > ip route-cache flow
> > ip route-cache distributed
> >
> > !
> > ip flow-export source Loopback0
> > ip flow-export version 6 origin-as
> > ip flow-export destination 10.1.1.1 2055
> >
> > Someone please help!
> >
> > Cheers
> > Christian Braun
> > --
> > cflowd mailing list
> > cflowd@caida.org
>
-- cflowd mailing list cflowd@caida.org