From: Stefan Watermann (stefan@debitel.net)
Date: Mon Feb 10 2003 - 10:58:52 PST
Hi all,
I'm using cflowd-2-1b1 to collect V5 and V8 Netflow data from our
Cisco 7xxx routers and Catalyst 6509 switches (running CatOS and IOS
on the MSFC). After changing from V7 to V8 on our Catalysts, I see
the following messages:
cflowdmux[21307]: [E] bogus agg_method (8) for v8 flow export {cflowdmux.cc:166}
Any ideas, what to do now?
Feb 10 16:06:21 sv2073 cflowdmux[21307]: [I] cflowdmux (version
cflowd-2-1-b1) started.
Feb 10 16:06:21 sv2073 cflowdmux[21307]: [I] created 2101248 byte packet
queue shmem segment {CflowdPacketQueue.cc:247}
Feb 10 16:06:21 sv2073 cflowdmux[21307]: [I] attached to 2101248 byte packet
queue at 0x401ad000
Feb 10 16:06:21 sv2073 cflowdmux[21307]: [I] created semaphore: id 786446
Feb 10 16:06:21 sv2073 cflowdmux[21307]: [I] set UDP recv queue to 261040
bytes for fd 4 (port 9800)
Feb 10 16:06:27 sv2073 cflowdmux[21307]: [E] bogus agg_method (8) for v8
flow export {cflowdmux.cc:166}
Feb 10 16:06:59 sv2073 last message repeated 6 times
Feb 10 16:07:23 sv2073 last message repeated 5 times
Feb 10 16:07:28 sv2073 cflowd[21319]: [I] cflowd (version cflowd-2-1-b1)
started.
Feb 10 16:07:28 sv2073 cflowd[21319]: [I] got semaphore: id 786446
Feb 10 16:07:28 sv2073 cflowd[21319]: [I] attached to 2101248 byte packet
queue at 0x40860000
Feb 10 16:07:31 sv2073 cflowdmux[21307]: [E] bogus agg_method (8) for v8
flow export {cflowdmux.cc:166}
Feb 10 16:08:03 sv2073 last message repeated 4 times
Feb 10 16:09:07 sv2073 last message repeated 11 times
Feb 10 16:10:11 sv2073 last message repeated 12 times
Feb 10 16:11:15 sv2073 last message repeated 13 times
cflowd.cf: (CatOS gear)
-----------------------
CISCOEXPORTER {
HOST: 10.10.210.5 # sr1-sc0.muc: IP address of Cisco
sending data.
ADDRESSES: { 10.10.210.5 } # Addresses of interfaces on Cisco
# sending data.
CFDATAPORT: 9800 # Port on which to listen for data.
SNMPCOMM: 'removed' # SNMP community name.
LOCALAS: 0 # Local AS of Cisco sending data.
COLLECT: { protocol, portmatrix, ifmatrix, nexthop, netmatrix,
asmatrix, tos, flows }
}
CatOS config:
-------------
#mls
set mls flow full
set mls nde version 8
set mls nde 10.10.10.32 9800
set mls nde enable
Many thanks in advance for any comment!
Cheers,
Stefan
-- Stefan Watermann stefan@debitel.net_______________________________________________ Cflowd mailing list Cflowd@caida.org http://login.caida.org/mailman/listinfo/cflowd
This archive was generated by hypermail 2.1.4 : Mon Feb 10 2003 - 11:11:13 PST